广州伟伯科技有限公司
您的位置:首页 > 产品中心 > HY-LiTE® Jet A1 Fuel ATP Test Kit
产品搜索:

HY-LiTE® Jet A1 Fuel ATP Test Kit

产品编号:4059983
规格: HY-LiTE®
包装规格:20 TEST
产品类别:进口试剂
品牌:Millipore
优惠价:立即咨询
产品价格
产品编号包装单位单价(元)国内现货国外库存询价单
405998320 TEST16010
产品别名

HY-LiTE® Jet A1 Fuel ATP Test Kit

Jet A1 Fuel biomass test, Rapid Jet A1 fuel test

产品性质
packaging【包装】
pkg of 20 tests (20 pens, 20 large pipettes, 20 small pipettes)
application(s)
environmental (Petroleum)
jet fuel
compatibility【相容性】
for use with HY-LITE®
Detection Method
bioluminescent
storage temp.【储存温度】
2-8℃
suitability【适用性】
For examination of biomass contamination of Jet A1 and other fuel samples
基本信息
General description【一般描述】
The HY-LiTE® Jet A1 Fuel ATP Test Kit contains ready-to-use pens for detection of total biological contamination of Jet A1 fuel used in conjunction with the HY-LiTE® 2/2A luminometer. Fuel contains small amounts of water and bears risk of microbial contamination. The biomass (e.g. bacteria, fungi) may grow and cause blocking of filters or corrosion of tanks, which is a very expensive issue in terms of unplanned maintenance in the hangar and days for microbiology test results.
Adenosine triphosphate (ATP) is detected by reaction with a luciferin/luciferase reagent in buffered solution. The test will detect the metabolic activity of bacteria, yeast and molds, including sulphate reducing bacteria and other anaerobe microorganisms, which are not always detected by traditional growth-based methods.
The test kit is designed to indicate presence of metabolically active biological material, but it is the nature of biology that there may be organisms present in the sample that are not detected by the test procedure. In particular, the results of any test procedure cannot be interpreted to indicate sterility of the sample tested.
Merck KGaA and its affiliates and appointed distributors do not accept any liability for any decision or assessment taken or made because of using this test kit.
MEASUREMENT LIMITS:
IATA (International Air Transport Association) “Guidance Material on Microbiological Contamination in Aircraft Fuel Tanks” 2nd Edition, February 2005 (ISBN 92-9195-437-3):
  • Negligible: < 1000 RLU/liter fuel
  • Moderate: 1000 – 5000 RLU/liter fuel
  • Heavy: > 5000 RLU/liter fuel
The limits suggested above are based on the HY-LiTE® 2 luminometer′s measurement scale. They apply only to Aircraft Wing Tank samples and are based on comparison with other routinely used methods. These limits are a suggestion only and may need to be adapted for other types of samples and according to individual circumstances, frequency of testing, history of contamination etc.
This fuel test kit contains patented capture solution for sampling from Jet A1 fuel samples.
Application【应用】
The HY-LiTE® Jet A1 Fuel Test Kit is suitable for rapid detection of microbiological contamination in fuel tanks and distribution systems.
Analysis Note【分析说明】
Packaging: Passes test
Appearance: Passes test
Performance test: Passes test
Legal Information【法律信息】
HY-LITE is a registered trademark of Merck KGaA, Darmstadt, Germany
安全信息
Storage Class Code【储存分类代码】
10 - Combustible liquids
广州伟伯科技有限公司 版权所有 CopyRight ©2006-2024, All Rights Reserved
工信部备案号:粤ICP备08114744号   Page Run Time: 0.0080