您的位置:首页 > 产品中心 > Opticap 无菌 XL 150 Millipore Express SHC 0.5/0.2 μm 9/16 in.HB/带灌注钟罩的 HB
Opticap 无菌 XL 150 Millipore Express SHC 0.5/0.2 μm 9/16 in.HB/带灌注钟罩的 HB
Opticap® XL150 Millipore Express® SHC
产品编号: | 4081803 |
规格: | sterile, inlet connection diam. 9/16 in., pore size 0.5/0.2 μm, cartridge nominal length 3.8 in. (9.7 cm) |
包装规格: | 3 EA |
产品类别: | 进口试剂 |
品牌: | Millipore |
优惠价: | 立即咨询 |
产品别名
Opticap
Opticap® XL150 Millipore Express® SHC
Opticap Sterile XL 150 Millipore Express SHC 0.5/0.2 μm 9/16 in. HB/HB with Bell
产品性质
Quality Level【质量水平】 | 400 |
material【物料】 | polyethersulfone polyethylene support polypropylene (gamma-stable) polypropylene housing polypropylene vent cap (Gamma stable) polysulfone silicone seal |
reg. compliance | meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials) |
sterility【无菌性】 | sterile |
product line【产品线】 | EMPROVE® Filter |
feature【特点】 | hydrophilic |
manufacturer/tradename | Millipore Express® |
parameter【参数】 | ≤1.0 mL/min air diffusion at 2.8 bar (40 psig) and 23 ℃ (in water) 1.0 bar max. differential pressure (15 psid) at 80 ℃ (Forward) 1.0 bar max. inlet pressure (15 psi) at 80 ℃ 100 psi max. differential pressure (6.9 bar) (intermittent) 2.1 bar max. differential pressure (30 psid) at 25 ℃ (Reverse; intermittent) 2.75 bar max. inlet pressure (40 psi) at 60 ℃ 25 ℃ max. inlet temp. 5.5 bar max. differential pressure (80 psid) at 25 ℃ (Forward) 5.5 bar max. inlet pressure (80 psi) at 23 ℃ 6.9 bar max. differential pressure (100 psid) at 25 ℃ (Forward; intermittent) 6.9 bar max. inlet pressure (100 psi) at 23 ℃ (intermittent) 80 psi max. differential pressure (5.5 bar) (continuous) 80 psig max. inlet pressure |
L【长度】 | 9.7 cm (3.8 in.) |
cartridge nominal length | 3.8 in. (9.7 cm) |
diam.【直径】 | 5.6 cm (2.2 in.) |
filtration area【过滤面积】 | 140 cm2 |
inlet connection diam. | 9/16 in. |
inlet to outlet W | 9.7 cm (3.8 in.) |
outlet connection diam. | 9/16 in. |
impurities【杂质】 | ≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction) <0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction) |
matrix【基质】 | Millipore Express® SHC |
pore size【孔径】 | 0.5/0.2 μm pore size |
bubble point | ≥4000 mbar (58 psig), air with water at 23 ℃ |
fitting【配件】 | inlet hose barb 14 mm ( outlet hose barb (with Bell) 14 mm ( |
packaging【包装】 | Double Easy-Open bag |
基本信息
General description【一般描述】 | Device Configuration: 取样皿滤膜 |
Other Notes【其他说明】 | These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices. Directions for Use
|
Preparation Note【制备说明】 | This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6). Sterilization Method 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable |
Analysis Note【分析说明】 | TOC/Conductivity After sterilization and a controlled water flush of 1.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C. Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L Bacterial Retention Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology. |
Legal Information【法律信息】 | ASTM is a registered trademark of American Society for Testing and Materials Emprove is a registered trademark of Merck KGaA, Darmstadt, Germany MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany |
产品说明
Disclaimer【免责声明】 | EMD Millipore Corporation |